The consumer is not allowed to open the handles and panel from the technique, neither Be aware: gadget disassemble is allowed. To ensure the method overall performance and safety, only Mindray engineers or engineers licensed by Mindray can carry out maintenance.

The DP-fifty Expert is an revolutionary, higher-functionality Ultrasound Process engineered to assist you obtain the insights you require. The Method’s powerful motor and substantial-pace processing supply fantastic picture excellent and a complete facts management Alternative.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits utilization of many scanned angles to kind one image, resulting in Increased distinction resolution and enhanced visualization

The chapter materials the tactic to confirm main function and general performance of product. This can be only utilized for reference, not preventive execution. Function checking and testing of this section shall be carried out by Mindray company engineers and also the person alongside one another. Web page 66: Basic Examination

Will not use any cables besides the cables presented While using the gadget by Mindray. 3. Use the cable provided with This technique to attach the printer. Other cables may perhaps lead to electrical shock. Webpage 15: Mechanical Protection

Performance Take a look at five.five.one Test Approach Resolution Detection depth Geometric Position Precision Blackout location test Report the exam photographs 5.5.2 Test Content material The impression utilized Here's just for reference, stick with the impression outcome in the true Be aware: predicament. Requirements: Show: established the contrast and brightness on the scientific application value (or even the default position) Operation surroundings: darkish space, simulating the clinical software setting. Web site 76 In affliction that the transverse resolution testing targets are horizontally shown, record the negligible distance of two targets that may be Obviously identified. Repeat the Procedure higher than for that transverse resolution screening targets at other depths. As shown in determine down below. Axial resolution ... Website page 77 When utilizing the convex probe, retain the transverse resolution tests targets to notice: be exhibited near the midline. When using a linear probe with steer functionality, usually do not turn on the steer functionality when complete the transverse resolution examination. Zoom during the region wherever the targets located if needed. The diameter of the target position at a particular depth is equivalent into the transverse resolution in the depth. Website page seventy eight five.

5.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Check Step: Do adjustments as the way in tests the utmost depth. Document the space by 20mm Each individual section within the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest mistake (to 20mm), compute the precision using the components underneath The measurement caliper must be positioned for the upper edge of the concentrate on, Notice:... Web page 79 Transverse geometric positioning precision  Test Action: Include the scan floor from the phantom with drinking water or pair gel, Carefully Speak to the probe With all the scan floor Modify the depth, building the transverse targets to become displayed in the picture. Alter the main focus issue to become posited beside the transverse targets (the common is not really very clear) Regulate parameters like gain, TGC, creating Every single transverse targets being Plainly shown. Website page 80 five.5.2.4 Blackout Spot Test Step: Cover the scan area on the phantom with drinking water or pair gel, Carefully Get hold of the probe Along with the scan floor Modify the depth in a decrease value, and set the main target at the nearest destination to the scan floor. Dp50rb login Reduce the worth of parameters like AP, Obtain till the history noise just could be seen. Site 81: Software package Improve And Routine maintenance

Greatest 4 times tasking for 1 transmitted beam, resulting in exceptional time resolution and higher body rate.

Our DP-fifty Rated units can endure hurricane-force winds as many as 173 mph. Focused on furnishing master wood entry doors to states with even the strictest making needs, DP-fifty Rated Units are DSA’s minimum amount Coastal Doorway Ranking which meets or exceeds most non-effect making specifications along the east coast.

Return to your system preset interface. The option status modifications into Uninstalled. The uninstalling operate is exceptional to inside end users.

Mindray’s new era of black & white ultrasound procedure, DP-fifty Expert, is equipped with State-of-the-art imaging systems allowing further penetration and faster image acquisition with larger resolution.

probe. The image abnormality may very well be because of Swap the probe, or the swivel of your 4D probe or even the 4D travel exchange the 4D travel board board.

Your Device for deeper biopsy: allowing for adjustments for the scan line to realize improved visibility of the needle, nerves and little vessels, guaranteeing the continuity of all facts.